Brocade Fiber Channel Fabric Element Status
Description
Applicable on all Fiber channel devices that support the FIBER-CHANNEL-FE-MIB and SW-MIB. Monitors the status of the fiber channel modules,port statistics like traffic rate on the port fiber elements,port status etc.,
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Fiber channel FE Module Status | fiberchannel.module.status | Fiber Channel Module Status | ||
Fiber Channel FE Port Stats - Ext | fiberchannel_port_available_buffers | Fiber Channel Port Available Buffers | count | |
fiberchannel_port_linkfailures | Fiber Channel Port Link Failures | psec | ||
fiberchannel_port_c3frame_discards | Fiber Channel Port Class 3 Frame Discards | psec | ||
fiberchannel_port_invalidtxwords | Fiber Channel Port Invalid Tx Words | psec | ||
fiberchannel_port_siglosses | Fiber Channel Port Signal Losses | psec | ||
fiberchannel_port_c3frames_out | Fiber Channel Port Class 3 Frames Out | psec | ||
fiberchannel_port_offlineseq_out | Fiber Channel Port Issued Offline Sequences | psec | ||
fiberchannel_port_offlineseq_in | Fiber Channel Port Received Offline Sequences | psec | ||
fiberchannel_port_c3frames_in | Fiber Channel Port Class 3 Frames In | psec | ||
fiberchannel_port_status | Fiber Channel Port Operational Status | |||
fiberchannel_port_invalidcrc | Fiber Channel Port Invalid CRCs | psec | ||
fiberchannel_port_synclosses | Fiber Channel Port Sync Losses | psec | ||
Fiber Channel Max FE Modules | fiberchannel.fabric.modules.max | Fiber Channel Fabric Modules Max |
Brocade Fiber Channel Fabric Element Status - v2
This template will be deprecated soon.
Description
Applicable on all Fiber channel devices that support the FIBER-CHANNEL-FE-MIB and SW-MIB. Monitors the status of the fiber channel modules,port statistics like traffic rate on the port fiber elements,port status. Added additional metrics like link reset ins,linkreset outs,crc errors,crc errors,crc errors with a good EOF. Validated on G620 switch.
Prerequisites
NULL
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Fiber Channel FE Port Stats Ext - v2 | fiberchannel_port_status | Fiber Channel Port Operational Status | Monitors the operational status of fiber channel port.[OIDs: 1.3.6.1.2.1.75.1.1.5.1.2,1.3.6.1.2.1.75.1.2.2.1.1,1.3.6.1.2.1.75.1.2.2.1.2] | |
fiberchannel_port_c3frame_discards | Fiber Channel Port Class 3 Frame Discards | psec | Monitors number of Class 3 frames discarded by this FxPort.[OID: 1.3.6.1.2.1.75.1.4.3.1.5] | |
fiberchannel_port_c3frames_in | Fiber Channel Port Class 3 Frames In | psec | Monitors the number of Class 3 frames received by this FxPort from its attached NxPort.[OID: 1.3.6.1.2.1.75.1.4.3.1.1] | |
fiberchannel_port_c3frames_out | Fiber Channel Port Class 3 Frames Out | psec | Monitors the number of Class 3 frames delivered through this FxPort to its attached NxPort.[OID: 1.3.6.1.2.1.75.1.4.3.1.2] | |
fiberchannel_port_linkreset_out | Fiberchannel Port Link ResetOut | psec | The number of Link Reset received by this FxPort.[1.3.6.1.2.1.75.1.3.1.1.10] | |
fiberchannel_port_offlineseq_in | Fiber Channel Port Received Offline Sequences | psec | Monitors the number of Offline Sequence received by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.11] | |
fiberchannel_port_linkfailures | Fiber Channel Port Link Failures | psec | Monitors the number of link failures detected by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.1] | |
fiberchannel_port_invalidtxwords | Fiber Channel Port Invalid Tx Words | psec | Monitors the number of invalid transmission word detected by the FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.5] | |
fiberchannel_port_offlineseq_out | Fiber Channel Port Issued Offline Sequences | psec | Monitors the number of Offline Sequence issued by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.12] | |
fiberchannel_port_invalidcrc | Fiber Channel Port Invalid CRCs | psec | Monitors the number of invalid CRC detected by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.6] | |
Fiber Channel CRC Erros - Ext | fiberchannel_port_invalid_crc_g_eof | Fiberchannel Port Invalid CRC Good EOF | Per Second | Monitors fiber channel switch port CRC errors with a good EOF.[1.3.6.1.3.94.4.5.1.40] |
fiberchannel_port_invalid_crc_erros | Fiberchannel Port Invalid CRC Errors | Per Second | Monitors the number of invalid CRC Errors.[1.3.6.1.4.1.1588.2.1.1.1.27.1.1] | |
Fiber Channel FE Port Stats Ext - v2 | fiberchannel_port_linkreset_in | Fiberchannel Port Link Resetin | psec | The number of Link Reset Protocol received by this FxPort.[1.3.6.1.2.1.75.1.3.1.1.9] |
fiberchannel_port_synclosses | Fiber Channel Port Sync Losses | psec | Monitors the number of loss of synchronization detected by the FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.2] | |
fiberchannel_port_available_buffers | Fiber Channel Port Available Buffers | count | Monitors the number of buffers currently available for receiving frames from the attached port in the buffer-to-buffer flow control.[OID: 1.3.6.1.2.1.75.1.2.1.1.2] | |
fiberchannel_port_siglosses | Fiber Channel Port Signal Losses | psec | Monitors the number of loss of signal detected by the FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.3] |
Brocade Fiber Channel Fabric Element Status - v3
Description
Applicable on all Fiber channel devices that support the FIBER-CHANNEL-FE-MIB and SW-MIB. Monitors the status of the fiber channel modules,port statistics like traffic rate on the port fiber elements,port status. Added additional metrics like link reset ins,linkreset outs,crc errors,crc errors,crc errors with a good EOF. Validated on G620 switch.
Prerequisites
NULL
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Fiber Channel FE Port Stats Ext - v2 | fiberchannel_port_c3frame_discards | Fiber Channel Port Class 3 Frame Discards | psec | Monitors number of Class 3 frames discarded by this FxPort.[OID: 1.3.6.1.2.1.75.1.4.3.1.5] |
fiberchannel_port_offlineseq_out | Fiber Channel Port Issued Offline Sequences | psec | Monitors the number of Offline Sequence issued by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.12] | |
fiberchannel_port_status | Fiber Channel Port Operational Status | Monitors the operational status of fiber channel port.[OIDs: 1.3.6.1.2.1.75.1.1.5.1.2,1.3.6.1.2.1.75.1.2.2.1.1,1.3.6.1.2.1.75.1.2.2.1.2] | ||
fiberchannel_port_linkfailures | Fiber Channel Port Link Failures | psec | Monitors the number of link failures detected by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.1] | |
fiberchannel_port_offlineseq_in | Fiber Channel Port Received Offline Sequences | psec | Monitors the number of Offline Sequence received by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.11] | |
fiberchannel_port_c3frames_in | Fiber Channel Port Class 3 Frames In | psec | Monitors the number of Class 3 frames received by this FxPort from its attached NxPort.[OID: 1.3.6.1.2.1.75.1.4.3.1.1] | |
fiberchannel_port_available_buffers | Fiber Channel Port Available Buffers | count | Monitors the number of buffers currently available for receiving frames from the attached port in the buffer-to-buffer flow control.[OID: 1.3.6.1.2.1.75.1.2.1.1.2] | |
fiberchannel_port_c3frames_out | Fiber Channel Port Class 3 Frames Out | psec | Monitors the number of Class 3 frames delivered through this FxPort to its attached NxPort.[OID: 1.3.6.1.2.1.75.1.4.3.1.2] | |
fiberchannel_port_siglosses | Fiber Channel Port Signal Losses | psec | Monitors the number of invalid CRC detected by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.6] | |
fiberchannel_port_linkreset_in | Fiberchannel Port Link Resetin | psec | The number of Link Reset Protocol received by this FxPort.[1.3.6.1.2.1.75.1.3.1.1.9] | |
fiberchannel_port_linkreset_out | Fiberchannel Port Link ResetOut | psec | The number of Link Reset received by this FxPort.[1.3.6.1.2.1.75.1.3.1.1.10] | |
fiberchannel_port_synclosses | Fiber Channel Port Sync Losses | psec | Monitors the number of loss of synchronization detected by the FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.2] | |
fiberchannel_port_invalidtxwords | Fiber Channel Port Invalid Tx Words | psec | Monitors the number of invalid transmission word detected by the FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.5] | |
fiberchannel_port_invalidcrc | Fiber Channel Port Invalid CRCs | psec | Monitors the number of invalid CRC detected by this FxPort.[OID: 1.3.6.1.2.1.75.1.3.1.1.6] | |
Fiber Channel CRC Erros Ext - v2 | fiberchannel_port_invalid_crc_g_eof | Fiberchannel Port Invalid CRC Good EOF | Per Second | Monitors fiber channel switch port CRC errors with a good EOF.[1.3.6.1.3.94.4.5.1.40] |
fiberchannel_port_invalid_crc_erros | Fiberchannel Port Invalid CRC Errors | Per Second | Monitors the number of invalid CRC Errors.[1.3.6.1.4.1.1588.2.1.1.1.27.1.1] |
Brocade FOS - Basic Performance
Description
This template is applicable on Brocade FOS devices. Monitors the basic prameters like CPU utilization,memory usage.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade FOS - Basic Performance | brocade_fos_cpu_Utilization | Brocade FOS CPU Utilization | % | It provides the brocade FOS devices CPU utilization.[SW-MIB::swCpuUsage:1.3.6.1.4.1.1588.2.1.1.1.26.1.0] |
brocade_fos_memory_Utilization | Brocade FOS Memory Utilization | % | It monitors the brocade fos devices memory utilization.[swMemUsage:1.3.6.1.4.1.1588.2.1.1.1.26.6.0] |
Brocade Foundry Switch Monitors - G2
Description
This template is applicable on Brocade Foundry switches. Monitors the status of power supply and fan. Also monitors temperature,CPU utilization,chassis CPU,memory usage.[Validate on Brocade ICX7250-24 switch. SysObjId: 1.3.6.1.4.1.1991.1.3.48.9.1].
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade - Foundry Switch Chassis Fan Status | chasis.fan.status | Chassis Fan Status | Monitors the fan operation status. Possible values are 1- other,2- normal,3- failure.[OIDs: 1.3.6.1.4.1.1991.1.1.1.3.1.1.2,1.3.6.1.4.1.1991.1.1.1.3.1.1.3] | |
Brocade - Foundry Switch Module CPU Utilization | module.cpu.util | Module CPU Utilization | % | Monitors the statistical CPU utilization in units of percent.[OIDs: 1.3.6.1.4.1.1991.1.1.2.11.1.1.1,1.3.6.1.4.1.1991.1.1.2.11.1.1.3,1.3.6.1.4.1.1991.1.1.2.11.1.1.4] |
Brocade - Foundry Switch Performance | system.cpu.utilization | CPU Utilization | % | Monitors the statistics collection of 1 minute CPU utilization.[OID: 1.3.6.1.4.1.1991.1.1.2.1.52.0] |
system.memory.util.percent | Memory Utilization | % | Monitors the system dynamic memory utilization,in unit of percentage.[OID: 1.3.6.1.4.1.1991.1.1.2.1.53.0] | |
system.memory.total | Memory Total | Bytes | Monitors the total amount of system dynamic memory,in number of bytes.[OID: 1.3.6.1.4.1.1991.1.1.2.1.54.0] | |
system.memory.free | Memory Free | Bytes | Monitors the free amount of system dynamic memory,in number of bytes.[OID: 1.3.6.1.4.1.1991.1.1.2.1.55.0] | |
Brocade - Foundry Switch Power Supply Status | chasis.power.staus | Chassis Power Status | Monitors the power supply operation status. Possible values are 1- other,2- normal,3- failure.[OIDs: 1.3.6.1.4.1.1991.1.1.1.2.1.1.2,1.3.6.1.4.1.1991.1.1.1.2.1.1.3] | |
Brocade - Foundry Switch Temperature | temperature | Temperature | C | Monitors the temperature of the sensor in degrees Celcius.[OIDs: 1.3.6.1.4.1.1991.1.1.2.13.1.1.3,1.3.6.1.4.1.1991.1.1.2.13.1.1.4] |
Brocade Hardware and Health Status
Description
Applicable on Brocade NOS and FOS devices.Monitors the status values of temperature,fan,power supply monitors and operational status,flash operational status.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade - Foundry Switch Temperature | temperature | Temperature | C | Monitors the temperature of the sensor in degrees Celcius.[OIDs: 1.3.6.1.4.1.1991.1.1.2.13.1.1.3,1.3.6.1.4.1.1991.1.1.2.13.1.1.4] |
Brocade FC Port Physical Status | brocade.switch.fc.port.physical.state | FC Port Physical State | This object identifies the physical state of the port: 1- No Card- no card present in this switch slot,2- No Transceiver- no transceiver module in this port (noGbic(2) was used previously. Transceiver is the generic name for GBIC,SFP etc),3- Laser Fault- the module is signaling a laser fault (defective Transceiver),4- No Light- the module is not receiving light,5- No Sync- the module is receiving light but is out of sync,6- In Sync- the module is receiving light and is in sync,7- Port Fault- the port is marked faulty (defective Transceiver,cable or device),8- DiagFault- the port failed diagnostics (defective G_Port or FL_Port card or motherboard),9- Lock Ref- the port is locking to the reference signal. Alert is generated when the physical state is equal to 4- No Light,7- Port Fault.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1,1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3] | |
Brocade SAN Switch Fan | system.fan.status | Fan Sensor Status | Monitors the current status of the fan sensor. Possible values are 1- normal,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
system.fan.speed | Fan Sensor Value | rpm | Monitors the current value (reading) of the fan sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
Brocade SAN Switch Operational Status | brocade.san.switch.operational.status | Switch Operational Status | Monitors the current operational status of the switch. Possible operational status values are 1- Online : the switch is accessible by an external fibre channel port,2- Offline : the switch is not accessible,3- Testing : the switch is in a built-in test mode and is not accessible by an external fibre channel port,4- Faulty : the switch is not operational.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.1.1.1.8] | |
brocade.san.switch.flash.operational.status | Flash Operational Status | Monitors the flash operational status of the switch. Possible flash operational status values are 0- Unknown,1- SW current : the flash contains the current firmware image or configuration file,2- SW fw upgraded : the flash contains the image upgraded from the flash DL host,3- SW Cf Uploaded : the switch configuration file has been uploaded to the host,4- SW Cf Downloaded : the switch configuration file has been downloaded from the host,5- SW Fw corrupted : the firmware in the flash of the switch is corrupted.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.11,1.3.6.1.4.1.1588.2.1.1.1.1.12] | ||
Brocade SAN Switch Power Supply | brocade.san.switch.power.supply.value | Power Supply Sensor Value | Monitors the current value (reading) of the power supply sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
brocade.san.switch.power.supply.status | Power Supply Sensor Status | Monitors the current status of the power supply sensor. Possible values are 1- unknown,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | ||
Brocade Switch Additional HA-MIB Monitors | brocade.switch.cp.status | Control Processor Status | Monitors the current status of the Control Processor (CP). Possible values are 1- other,2- unknown,3- active,4- standby,5- failed.[OIDs: 1.3.6.1.2.1.47.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.2.1.7.1.1] | |
brocade.switch.fru.status | FRU Status | Monitors the current status of the FRU object in the slot. Possible values are 1- other,2- unknown,3- on,4- off,5- faulty.[OIDs: 1.3.6.1.4.1.1588.2.1.2.1.5.1.2,1.3.6.1.2.1.47.1.1.1.1.7] | ||
brocade.switch.bp.status | Blade Processor Status | Monitors the Blade Processor (BP) status. Possible values are 1- on,2- off,3- faulty,4- unknown,5- others.[OIDs: 1.3.6.1.2.1.47.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.2.1.8.1.1] | ||
Brocade Switch Status | brocade.switch.ha.status | High Availability Status | Monitors whether the system is redundant or not. Possible value are 0- redundant,1- nonredundant.[OID: 1.3.6.1.4.1.1588.2.1.2.1.1.0] | |
brocade.switch.beacon.operational.status | Switch Beacon Operational Status | Monitors the current operational status of the switch beacon. When the beacon is on (1),the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off (2),each LED will be in their its regular status indicating color and state.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.18.0] |
Brocade Ironware - Basic Performance
Description
This template is applicable on Brocade Ironware devices. Monitors the basic prameters like CPU utilization,memory usage.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade Ironware Switch Basic monitoring | Brocade_ironware_os_cpu_Utilization | Brocade Ironware OS CPU Utilization | % | It monitors the brocade ironware OS switch CPU utilization.[FOUNDRY-SN-AGENT-MIB::snAgGblCpuUtil1MinAvg:1.3.6.1.4.1.1991.1.1.2.1.52.0] |
brocade_ironware_os_memory_Utilization | Brocade Ironware OS Memory Utilization | % | It monitors the brocade ironware OS memory utilization.[FOUNDRY-SN-AGENT-MIB::snAgGblDynMemUtil:1.3.6.1.4.1.1991.1.1.2.1.53.0] |
Brocade NOS - Basic Performance
Description
This template is applicable on Brocade NOS devices. Monitors the basic prameters like CPU utilization,memory usage.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade NOS - Basic Performance | brocade_nos_memory_Utilization | Brocade NOS Memory Utilization | % | It monitors the brocade nos devices memory utilization.[swMemUsage:1.3.6.1.4.1.1588.2.1.1.1.26.6.0] |
brocade_nos_cpu_Utilization | Brocade NOS CPU Utilization | % | It provides the brocade NOS devices CPU utilization.[SW-MIB::swCpuUsage:1.3.6.1.4.1.1588.2.1.1.1.26.1.0] |
Brocade SAN Switch - Enhanced
Description
This template serves as an alternative to the Brocade SAN Switch Status - G2 template, featuring the following updates:
- Poll Interval: Decreased to 5 minutes for more frequent monitoring.
- Additional Metrics:
- CRC Errors
- Encoding (ENC) Errors
Features This template is designed for Brocade SAN Switches and supports the following functionalities:
- Monitors the status of:
- Temperature
- Fan
- Power Supply
- Operational Status
- Flash Operational Status
- SFP Stats
- Applicability: Tested on Brocade Silkworm Series and VDX Series Fibre Channel Switches.
Recommendations
- Use the Fiber Channel templates alongside this template for comprehensive monitoring.
Validated SysObjectId - 1.3.6.1.4.1.1588.2.1.1.148
Prerequisites
Device should support SW-MIB
Supported Metrics
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade Switch CRC And Encoding(ENC) Errors | brocade_switch_fc_port_rx_crc_errors_CounterValue | Brocade Switch FC Port Rx Crc Errors Counter Value | count | It monitors the number of CRC errors detected for the frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxCrcs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22) |
brocade_switch_fc_port_rx_crc_errors_CounterDelta | Brocade Switch FC Port Rx Crc Errors Counter Delta | This monitors the number of delta CRC errors detected for the frames received. Here Counter Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxCrcs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22) | ||
brocade_switch_fc_port_rx_enc_errors_in_CounterValue | Brocade Switch FC Port Rx Enc Errors Counter Value | It monitors the number of encoding error or disparity error inside frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncInFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21) | ||
brocade_switch_fc_port_rx_enc_errors_in_CounterDelta | Brocade Switch FC Port Rx Enc Errors Counter Delta | It monitors the number of encoding errors in Delta or disparity errors in the frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncInFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21) | ||
brocade_switch_fc_port_rx_enc_errors_out_CounterValue | Brocade Switch FC Port Rx Enc Errors Counter Value | It monitors the number of encoding error or disparity error outside frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncOutFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26) | ||
brocade_switch_fc_port_rx_enc_errors_out_CounterDelta | Brocade Switch FC Port Rx Enc Errors Out Counter Delta | It monitors the number of encoding error or disparity error outside frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncOutFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26) | ||
Brocade Switch Additional Monitors | brocade.switch.beacon.operational.status | Switch Beacon Operational Status | Monitors the current operational status of the switch beacon. When the beacon is on (1), the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off (2), each LED will be in its regular status indicating color and state. [OID: 1.3.6.1.4.1.1588.2.1.1.1.1.18.0] | |
brocade.switch.cpu.utilization | Switch CPU Utilization | % | Monitors the system's CPU usage. [OID: 1.3.6.1.4.1.1588.2.1.1.1.26.1.0] | |
brocade.switch.memory.utilization | Switch Memory Utilization | % | Monitors the system's memory usage. [OID: 1.3.6.1.4.1.1588.2.1.1.1.26.6.0] | |
brocade.switch.ha.status | High Availability Status | Monitors whether the system is redundant or not. Possible values are 0- redundant, 1- nonredundant. [OID: 1.3.6.1.4.1.1588.2.1.2.1.1.0] | ||
Brocade Switch Additional HA-MIB Monitors | brocade.switch.fru.status | FRU Status | Monitors the current status of the FRU object in the slot. Possible values are 1- other, 2- unknown, 3- on, 4- off, 5- faulty. [OIDs: 1.3.6.1.4.1.1588.2.1.2.1.5.1.2, 1.3.6.1.2.1.47.1.1.1.1.7] | |
brocade.switch.cp.status | Control Processor Status | Monitors the current status of the Control Processor (CP). Possible values are 1- other, 2- unknown, 3- active, 4- standby, 5- failed. [OIDs: 1.3.6.1.2.1.47.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.2.1.7.1.1] | ||
brocade.switch.bp.status | Blade Processor Status | Monitors the Blade Processor (BP) status. Possible values are 1- on, 2- off, 3- faulty, 4- unknown, 5- others. [OIDs: 1.3.6.1.2.1.47.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.2.1.8.1.1] | ||
Brocade FC Port Physical Status | brocade.switch.fc.port.physical.state | FC Port Physical State | This object identifies the physical state of the port: 1- No Card- no card present in this switch slot, 2- No Transceiver- no transceiver module in this port (noGbic(2) was used previously. Transceiver is the generic name for GBIC, SFP etc), 3- Laser Fault- the module is signaling a laser fault (defective Transceiver), 4- No Light- the module is not receiving light, 5- No Sync- the module is receiving light but is out of sync, 6- In Sync- the module is receiving light and is in sync, 7- Port Fault- the port is marked faulty (defective Transceiver, cable or device), 8- DiagFault- the port failed diagnostics (defective G_Port or FL_Port card or motherboard), 9- Lock Ref- the port is locking to the reference signal. Alert is generated when the physical state is equal to 4- No Light, 7- Port Fault. [OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1, 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3] | |
Brocade SAN Switch Fan | system.fan.status | Fan Sensor Status | Monitors the current status of the fan sensor. Possible values are 1- normal,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
system.fan.speed | Fan Sensor Value | rpm | Monitors the current value (reading) of the fan sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
Brocade SAN Switch Operational Status | brocade.san.switch.operational.status | Switch Operational Status | Monitors the current operational status of the switch. Possible operational status values are 1- Online : the switch is accessible by an external fibre channel port,2- Offline : the switch is not accessible,3- Testing : the switch is in a built-in test mode and is not accessible by an external fibre channel port,4- Faulty : the switch is not operational.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.1.1.1.8] | |
brocade.san.switch.flash.operational.status | Flash Operational Status | Monitors the flash operational status of the switch. Possible flash operational status values are 0- Unknown,1- SW current : the flash contains the current firmware image or configuration file,2- SW fw upgraded : the flash contains the image upgraded from the flash DL host,3- SW Cf Uploaded : the switch configuration file has been uploaded to the host,4- SW Cf Downloaded : the switch configuration file has been downloaded from the host,5- SW Fw corrupted : the firmware in the flash of the switch is corrupted.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.11,1.3.6.1.4.1.1588.2.1.1.1.1.12] | ||
Brocade SAN Switch Power Supply | brocade.san.switch.power.supply.value | Power Supply Sensor Value | Monitors the current value (reading) of the power supply sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
brocade.san.switch.power.supply.status | Power Supply Sensor Status | Monitors the current status of the power supply sensor. Possible values are 1- unknown,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | ||
Brocade SAN Switch SFP Current | brocade.san.switch.sfp.current | SFP Current | amps | Monitors the current of SFP in amps.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3] |
Brocade SAN Switch SFP Rx Power | brocade.san.switch.sfp.rxpower | SFP Rx Power | dBm | Monitors the Rx power consumption of SFP in dBm.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4] |
Brocade SAN Switch SFP Temperature | brocade.san.switch.sfp.temperature | SFP Temperature | C | Monitors the temperature of SFP in centigrade.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.1] |
Brocade SAN Switch SFP Tx Power | brocade.san.switch.sfp.txpower | SFP Tx Power | dBm | Monitors the Tx power consumption of SFP.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5] |
Brocade SAN Switch SFP Voltage | brocade.san.switch.sfp.voltage | SFP Voltage | mV | Monitors the voltage of SFP in millivolts.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.2] |
Brocade SAN Switch Temperature | system.temperature.status | Temperature Sensor Status | Monitors the current status of the temperature sensor. Possible values are 1- unknown,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
system.temperature.value | Temperature Sensor Value | C | Monitors the current value (reading) of the temperature sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
Brocade Switch FC Port Operational Status | switch.fiberchannel.port.oper.status | Switch FC Port Operational Status | Monitors the the operational status of the port. The online(1) state indicates that user frames can be passed. The unknown(0) state indicates that likely the port module is physically absent. Other possible states are 2- Offline,3- testing,4- faulty.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4,1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5,1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36] |
Brocade SAN Switch Status - G2
Description
Applicable on Brocade SAN switch. Tested on a Brocade Silkworm series and VDX Series Fibre Channel Switch. Monitors the status values of temperature,fan,power supply monitors and operational status,flash operational status and SFP stats etc.,Use the Fiber Channel templates along with this template.
Prerequisites
No prerequisite
Supported Metrics
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade Switch CRC And Encoding(ENC) Errors | brocade_switch_fc_port_rx_crc_errors_CounterValue | Brocade Switch FC Port Rx Crc Errors Counter Value | count | It monitors the number of CRC errors detected for the frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxCrcs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22) |
brocade_switch_fc_port_rx_crc_errors_CounterDelta | Brocade Switch FC Port Rx Crc Errors Counter Delta | This monitors the number of delta CRC errors detected for the frames received. Here Counter Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxCrcs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.22) | ||
brocade_switch_fc_port_rx_enc_errors_in_CounterValue | Brocade Switch FC Port Rx Enc Errors Counter Value | It monitors the number of encoding error or disparity error inside frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncInFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21) | ||
brocade_switch_fc_port_rx_enc_errors_in_CounterDelta | Brocade Switch FC Port Rx Enc Errors Counter Delta | It monitors the number of encoding errors in Delta or disparity errors in the frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncInFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.21) | ||
brocade_switch_fc_port_rx_enc_errors_out_CounterValue | Brocade Switch FC Port Rx Enc Errors Counter Value | It monitors the number of encoding error or disparity error outside frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncOutFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26) | ||
brocade_switch_fc_port_rx_enc_errors_out_CounterDelta | Brocade Switch FC Port Rx Enc Errors Out Counter Delta | It monitors the number of encoding error or disparity error outside frames received. Delta refers to the difference between the current error count and the previous error count. (SW-MIB :: swFCPortRxEncOutFrs : 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.26) | ||
Brocade Switch Additional HA-MIB Monitors | brocade.switch.fru.status | FRU Status | Monitors the current status of the FRU object in the slot. Possible values are 1- other, 2- unknown, 3- on, 4- off, 5- faulty. [OIDs: 1.3.6.1.4.1.1588.2.1.2.1.5.1.2, 1.3.6.1.2.1.47.1.1.1.1.7] | |
brocade.switch.cp.status | Control Processor Status | Monitors the current status of the Control Processor (CP). Possible values are 1- other, 2- unknown, 3- active, 4- standby, 5- failed. [OIDs: 1.3.6.1.2.1.47.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.2.1.7.1.1] | ||
brocade.switch.bp.status | Blade Processor Status | Monitors the Blade Processor (BP) status. Possible values are 1- on, 2- off, 3- faulty, 4- unknown, 5- others. [OIDs: 1.3.6.1.2.1.47.1.1.1.1.7, 1.3.6.1.4.1.1588.2.1.2.1.8.1.1] | ||
Brocade Switch Additional HA-MIB Monitors | brocade.switch.fru.status | FRU Status | Monitors the current status of the FRU object in the slot. Possible values are 1- other, 2- unknown, 3- on, 4- off, 5- faulty. [OIDs: 1.3.6.1.4.1.1588.2.1.2.1.5.1.2, 1.3.6.1.2.1.47.1.1.1.1.7] | |
Brocade FC Port Physical Status | brocade.switch.fc.port.physical.state | FC Port Physical State | This object identifies the physical state of the port: 1- No Card- no card present in this switch slot,2- No Transceiver- no transceiver module in this port (noGbic(2) was used previously. Transceiver is the generic name for GBIC,SFP etc),3- Laser Fault- the module is signaling a laser fault (defective Transceiver),4- No Light- the module is not receiving light,5- No Sync- the module is receiving light but is out of sync,6- In Sync- the module is receiving light and is in sync,7- Port Fault- the port is marked faulty (defective Transceiver,cable or device),8- DiagFault- the port failed diagnostics (defective G_Port or FL_Port card or motherboard),9- Lock Ref- the port is locking to the reference signal. Alert is generated when the physical state is equal to 4- No Light,7- Port Fault.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.1,1.3.6.1.4.1.1588.2.1.1.1.6.2.1.3] | |
Brocade SAN Switch Fan | system.fan.status | Fan Sensor Status | Monitors the current status of the fan sensor. Possible values are 1- normal,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
system.fan.speed | Fan Sensor Value | rpm | Monitors the current value (reading) of the fan sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
Brocade SAN Switch Operational Status | brocade.san.switch.operational.status | Switch Operational Status | Monitors the current operational status of the switch. Possible operational status values are 1- Online : the switch is accessible by an external fibre channel port,2- Offline : the switch is not accessible,3- Testing : the switch is in a built-in test mode and is not accessible by an external fibre channel port,4- Faulty : the switch is not operational.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.1.1.1.8] | |
brocade.san.switch.flash.operational.status | Flash Operational Status | Monitors the flash operational status of the switch. Possible flash operational status values are 0- Unknown,1- SW current : the flash contains the current firmware image or configuration file,2- SW fw upgraded : the flash contains the image upgraded from the flash DL host,3- SW Cf Uploaded : the switch configuration file has been uploaded to the host,4- SW Cf Downloaded : the switch configuration file has been downloaded from the host,5- SW Fw corrupted : the firmware in the flash of the switch is corrupted.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.11,1.3.6.1.4.1.1588.2.1.1.1.1.12] | ||
Brocade SAN Switch Power Supply | brocade.san.switch.power.supply.status | Power Supply Sensor Status | Monitors the current status of the power supply sensor. Possible values are 1- unknown,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
brocade.san.switch.power.supply.value | Power Supply Sensor Value | Monitors the current value (reading) of the power supply sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | ||
Brocade SAN Switch SFP Current | brocade.san.switch.sfp.current | SFP Current | amps | Monitors the current of SFP in amps.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3] |
Brocade SAN Switch SFP Rx Power | brocade.san.switch.sfp.rxpower | SFP Rx Power | dBm | Monitors the Rx power consumption of SFP in dBm.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4] |
Brocade SAN Switch SFP Temperature | brocade.san.switch.sfp.temperature | SFP Temperature | C | Monitors the temperature of SFP in centigrade.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.1] |
Brocade SAN Switch SFP Tx Power | brocade.san.switch.sfp.txpower | SFP Tx Power | dBm | Monitors the Tx power consumption of SFP.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5] |
Brocade SAN Switch SFP Voltage | brocade.san.switch.sfp.voltage | SFP Voltage | mV | Monitors the voltage of SFP in millivolts.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.2] |
Brocade SAN Switch Temperature | system.temperature.status | Temperature Sensor Status | Monitors the current status of the temperature sensor. Possible values are 1- unknown,2- faulty,3- below-min,4- nominal,5- above-max,6- absent.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
system.temperature.value | Temperature Sensor Value | C | Monitors the current value (reading) of the temperature sensor. The value,-2147483648,represents an unknown quantity. It also means that the sensor does not have the capability to measure the actual value.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.22.1.5,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.3,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.4,1.3.6.1.4.1.1588.2.1.1.1.1.22.1.2] | |
Brocade Switch Additional HA-MIB Monitors | brocade.switch.fru.status | FRU Status | Monitors the current status of the FRU object in the slot. Possible values are 1- other,2- unknown,3- on,4- off,5- faulty.[OIDs: 1.3.6.1.4.1.1588.2.1.2.1.5.1.2,1.3.6.1.2.1.47.1.1.1.1.7] | |
brocade.switch.cp.status | Control Processor Status | Monitors the current status of the Control Processor (CP). Possible values are 1- other,2- unknown,3- active,4- standby,5- failed.[OIDs: 1.3.6.1.2.1.47.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.2.1.7.1.1] | ||
brocade.switch.bp.status | Blade Processor Status | Monitors the Blade Processor (BP) status. Possible values are 1- on,2- off,3- faulty,4- unknown,5- others.[OIDs: 1.3.6.1.2.1.47.1.1.1.1.7,1.3.6.1.4.1.1588.2.1.2.1.8.1.1] | ||
Brocade Switch Additional Monitors | brocade.switch.beacon.operational.status | Switch Beacon Operational Status | Monitors the current operational status of the switch beacon. When the beacon is on (1),the LEDs on the front panel of the switch run alternately from left to right and right to left. The color is yellow. When the beacon is off (2),each LED will be in their its regular status indicating color and state.[OID: 1.3.6.1.4.1.1588.2.1.1.1.1.18.0] | |
brocade.switch.cpu.utilization | Switch CPU Utilization | % | Monitors the system's cpu usage.[OID: 1.3.6.1.4.1.1588.2.1.1.1.26.1.0] | |
brocade.switch.memory.utilization | Switch Memory Utilization | % | Monitors the system's memory usage.[OID: 1.3.6.1.4.1.1588.2.1.1.1.26.6.0] | |
brocade.switch.ha.status | High Availability Status | Monitors whether the system is redundant or not. Possible value are 0- redundant,1- nonredundant.[OID: 1.3.6.1.4.1.1588.2.1.2.1.1.0] | ||
Brocade Switch FC Port Operational Status | switch.fiberchannel.port.oper.status | Switch FC Port Operational Status | Monitors the the operational status of the port. The online(1) state indicates that user frames can be passed. The unknown(0) state indicates that likely the port module is physically absent. Other possible states are 2- Offline,3- testing,4- faulty.[OIDs: 1.3.6.1.4.1.1588.2.1.1.1.6.2.1.4,1.3.6.1.4.1.1588.2.1.1.1.6.2.1.5,1.3.6.1.4.1.1588.2.1.1.1.6.2.1.36] |
Brocade SFP Statistics
Description
Applicable on Brocade FOS devices. Monitors the SFP statistics.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade SAN Switch SFP Stats | brocade.san.switch.sfp.temperature | SFP Temperature | C | Monitors the temperature of SFP in centigrade.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.1] |
brocade.san.switch.sfp.voltage | SFP Voltage | mV | Monitors the voltage of SFP in millivolts.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.2] | |
brocade.san.switch.sfp.rxpower | SFP Rx Power | dBm | Monitors the Rx power consumption of SFP in dBm.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.4] | |
brocade.san.switch.sfp.txpower | SFP Tx Power | dBm | Monitors the Tx power consumption of SFP.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.5] | |
brocade.san.switch.sfp.current | SFP Current | amps | Monitors the current of SFP in amps.[OID: 1.3.6.1.4.1.1588.2.1.1.1.28.1.1.3] |
Brocade Silkworm FC Switch
Description
Template to monitor Brocade’s Silkworm Series Fibre Channel Switch Operational Status and its Statistics like Class3 Discards,Invalid Words,Link Loss,Signal Loss,Sync Loss.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade Switch - FiberChannel Port Class3 Discards | brocade.fiberchannel.port.class3.discards | FiberChannel Port Class3 Discards | psec | It monitors the number of Class 3 frames that the port has discarded.[SW-MIB::swFCPortC3Discards:1.3.6.1.4.1.1588.2.1.1.1.6.2.1.28]. |
Brocade Switch - RLS Statistics | brocade.rls.invalid.words | RLS - Invalid Words | count | It monitors the invalid word count for the end device RLS (Read Link Status).Component is represented as Port of the end device and Alpa of the end device with dotted separation.[SW-MIB::swEndDeviceInvalidWord:1.3.6.1.4.1.1588.2.1.1.1.21.1.1.8]. |
brocade.rls.signal.loss | RLS - Signal Loss | count | It monitors the signal loss count for the end device RLS (Read Link Status).Component is represented as Port of the end device and Alpa of the end device with dotted separation.[SW-MIB::swEndDeviceSigLoss:1.3.6.1.4.1.1588.2.1.1.1.21.1.1.6]. | |
brocade.rls.sync.loss | RLS - Sync Loss | count | It monitors the sync loss count for the end device RLS(Read Link Status).Component is represented as Port of the end device and Alpa of the end device with dotted separation.[SW-MIB::swEndDeviceSyncLoss:1.3.6.1.4.1.1588.2.1.1.1.21.1.1.5]. | |
brocade.rls.link.loss | RLS - Link Loss | count | It monitors the link failures count for the end device RLS (Read Link Status).Component is represented as Port of the end device and Alpa of the end device with dotted separation.[SW-MIB::swEndDeviceLinkFailure:1.3.6.1.4.1.1588.2.1.1.1.21.1.1.4]. | |
Brocade Switch - Status | brocade.switch.operational.status | Switch Operational Status | It monitors the current operational status of the switch. Possible values are 1: online,2: offline,3: testing,4: faulty.[SW-MIB::swOperStatus:1.3.6.1.4.1.1588.2.1.1.1.1.7.0]. |
Brocade ZXTM (Virtual Traffic Manager) - Node
Description
Template to monitor Brocade ZXTM (Virtual Traffic Manager) Node parameters like Node State,Traffic In,Traffic Out,Current TCP Connections,Pooled Connections,New Connections and Failures. Validated on Brocade Virtual Traffic Manager v10.1.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade ZXTM - Node | brocade.zxtm.node.traffic.in | Node - Traffic In | Kbps | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node incoming traffic.[ZXTM-MIB-SMIv2::nodeInet46BytesToNode - 1.3.6.1.4.1.7146.1.2.4.4.1.21] |
brocade.zxtm.node.pooled.conn | Node - Pooled Connections | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node Pooled Connections (Requests that reused an existing pooled/keepalive connection rather than creating a new TCP connection) [ZXTM-MIB-SMIv2::nodeInet46PooledConn - 1.3.6.1.4.1.7146.1.2.4.4.1.12] | ||
brocade.zxtm.node.state | Node - State | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node state. Possible state values are 1: alive,2: dead and 3: unknown [ZXTM-MIB-SMIv2::nodeInet46State 1.3.6.1.4.1.7146.1.2.4.4.1.5] | ||
brocade.zxtm.node.current.conn | Node - Current Connections | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node Current Connections (Current connections established to this node,includes idle connections) [ZXTM-MIB-SMIv2::nodeInet46CurrentConn - 1.3.6.1.4.1.7146.1.2.4.4.1.20] | ||
brocade.zxtm.node.new.conn | Node - New Connections | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node New Connections (Requests that created a new connection to this node).[ZXTM-MIB-SMIv2::nodeInet46NewConn - 1.3.6.1.4.1.7146.1.2.4.4.1.14] | ||
brocade.zxtm.node.traffic.out | Node - Traffic Out | Kbps | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node outgoing traffic.[ZXTM-MIB-SMIv2::nodeInet46BytesFromNode - 1.3.6.1.4.1.7146.1.2.4.4.1.22] | |
brocade.zxtm.node.failures | Node - Failures | It monitors Brocade ZXTM (Virtual Traffic Manager) - Node Failures.[ZXTM-MIB-SMIv2::nodeInet46Failures - 1.3.6.1.4.1.7146.1.2.4.4.1.13] |
Brocade ZXTM (Virtual Traffic Manager) - System Performance
Description
Template to monitor Brocade ZXTM (Virtual Traffic Manager) system performance parameters like CPU,Memory,Swap Memory,Traffic,TCP Connections and Uptime. Validated on Brocade Virtual Traffic Manager v10.1.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade ZXTM - CPU Stats | brocade.zxtm.sys.cpu.idle | CPUs Idle % | % | It monitors Brocade ZXTM (Virtual Traffic Manager) system CPU statistics like Percentage of time that the CPUs are idle.[ZXTM-MIB-SMIv2::sysCPUIdlePercent 1.3.6.1.4.1.7146.1.2.1.45.0] |
brocade.zxtm.sys.cpu.user | CPUs User Busy % | % | It monitors Brocade ZXTM (Virtual Traffic Manager) system CPU statistics like percentage of time that the CPUs are busy running user-space code.[ZXTM-MIB-SMIv2::sysCPUUserBusyPercent - 1.3.6.1.4.1.7146.1.2.1.47.0] | |
brocade.zxtm.sys.cpu.system | CPUs System Busy % | % | It monitors Brocade ZXTM (Virtual Traffic Manager) system CPU statistics like percentage of time that the CPUs are busy running system code.[ZXTM-MIB-SMIv2::sysCPUSystemBusyPercent 1.3.6.1.4.1.7146.1.2.1.48.0] | |
Brocade ZXTM - CPU Utilization | brocade.zxtm.sys.cpu.utilization | CPU Utilization | % | It monitors Brocade ZXTM (Virtual Traffic Manager) System CPU Utilization in %.[ZXTM-MIB-SMIv2::sysCPUBusyPercent - 1.3.6.1.4.1.7146.1.2.1.46.0] |
Brocade ZXTM - Memory | brocade.zxtm.sys.memory.used | Memory Used | MB | It monitors Brocade ZXTM (Virtual Traffic Manager) system memory used (MBytes).[ZXTM-MIB-SMIv2::sysMemInUse - 1.3.6.1.4.1.7146.1.2.1.52.0] |
brocade.zxtm.sys.memory.free | Memory Free | MB | It monitors Brocade ZXTM (Virtual Traffic Manager) system free memory (MBytes).[ZXTM-MIB-SMIv2::sysMemFree - 1.3.6.1.4.1.7146.1.2.1.51.0] | |
brocade.zxtm.sys.memory.utilization | Memory Utilization | % | It monitors Brocade ZXTM (Virtual Traffic Manager) system memory utilization(%).[ZXTM-MIB-SMIv2::sysMemTotal - 1.3.6.1.4.1.7146.1.2.1.50.0,sysMemInUse - 1.3.6.1.4.1.7146.1.2.1.52.0] | |
Brocade ZXTM - Network Traffic | brocade.zxtm.total.traffic.in | Traffic In - Total | Kbps | It monitors Brocade ZXTM (Virtual Traffic Manager) - Total Incoming traffic (from clients to traffic manager).[ZXTM-MIB-SMIv2::totalBytesIn - 1.3.6.1.4.1.7146.1.2.1.64.0] |
brocade.zxtm.total.traffic.out | Traffic Out - Total | Kbps | It monitors Brocade ZXTM (Virtual Traffic Manager) - Total outgoing traffic (from traffic manager to clients).[ZXTM-MIB-SMIv2::totalBytesOut - 1.3.6.1.4.1.7146.1.2.1.65.0] | |
Brocade ZXTM - Swap Memory | brocade.zxtm.sys.swap.memory.utilization | Swap Memory Utilization | % | It monitors Brocade ZXTM (Virtual Traffic Manager) system's swap space utilization in %.[ZXTM-MIB-SMIv2::sysMemSwapped - 1.3.6.1.4.1.7146.1.2.1.54.0,sysMemSwapTotal - 1.3.6.1.4.1.7146.1.2.1.55.0] |
brocade.zxtm.sys.swap.memory.free | Swap Memory Free | MB | It monitors Brocade ZXTM (Virtual Traffic Manager) system's amount of swap space free (MBytes).[ZXTM-MIB-SMIv2::sysMemSwapped - 1.3.6.1.4.1.7146.1.2.1.54.0,sysMemSwapTotal - 1.3.6.1.4.1.7146.1.2.1.55.0] | |
brocade.zxtm.sys.swap.memory.used | Swap Memory Used | MB | It monitors Brocade ZXTM (Virtual Traffic Manager) system's amount of swap space in use (MBytes).[ZXTM-MIB-SMIv2::sysMemSwapped - 1.3.6.1.4.1.7146.1.2.1.54.0] | |
Brocade ZXTM - Total Current Connections | brocade.zxtm.total.current.conn | Total Current Connections | It monitors Brocade ZXTM (Virtual Traffic Manager) - Number of TCP connections currently established.[ZXTM-MIB-SMIv2::totalCurrentConn - 1.3.6.1.4.1.7146.1.2.1.9.0] | |
System Uptime | system.uptime | System Uptime | s | The time since the SNMP agent in the system was last re-initialized.[OID : 1.3.6.1.2.1.1.3.0] |
Brocade ZXTM (Virtual Traffic Manager) - Virtual Server
Description
Template to monitor Brocade ZXTM (Virtual Traffic Manager) Virtual Server parameters like Traffic in,Traffic out,Discards,Direct replies,Connection timeouts,Data timeouts,Current Connections,Client Keep Alive Timeouts,Gzip connections,HTTP Cache Hits,HTTP Cache Lookups,HTTP Location Headers Rewritten and HTTP Cookies Rewritten. Validated on Brocade Virtual Traffic Manager v10.1.
Prerequisites
No prerequisite
Supported Metric
Monitor Name | Metric Name | Metric Display Name | Unit | Description |
---|---|---|---|---|
Brocade ZXTM - Virtual Server Connections | brocade.zxtm.virtual.server.keepalive.timeouts | Virtual Server - Client Keepalive Timeouts | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server Client Keepalive Timeouts (Connections closed by this virtual server because the 'keepalive_timeout' interval was exceeded).[ZXTM-MIB-SMIv2::virtualserverKeepaliveTimedOut - 1.3.6.1.4.1.7146.1.2.2.2.1.16] | |
brocade.zxtm.virtual.server.current.conn | Virtual Server - Current Connections | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server Current Connections(TCP connections currently established to this virtual server).[ZXTM-MIB-SMIv2::virtualserverCurrentConn - 1.3.6.1.4.1.7146.1.2.2.2.1.9] | ||
brocade.zxtm.virtual.server.conn.using.gzip | Virtual Server - Connections using Gzip | Connections using Gzip(Responses which have been compressed by content compression) [ZXTM-MIB-SMIv2:: virtualserverGzip - 1.3.6.1.4.1.7146.1.2.2.2.1.19] | ||
Brocade ZXTM - Virtual Server HTTP Cache | brocade.zxtm.virtual.server.http.cache.lookups | Virtual Server - HTTP Cache Lookups | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server HTTP Cache Lookups(HTTP requests that are looked up in the web cache by this virtual server).[ZXTM-MIB-SMIv2::virtualserverHttpCacheLookups - 1.3.6.1.4.1.7146.1.2.2.2.1.25] | |
brocade.zxtm.virtual.server.http.cache.hits | Virtual Server - HTTP Cache Hits | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server HTTP Cache Hits(HTTP responses sent directly from the web cache by this virtual server).[ZXTM-MIB-SMIv2::virtualserverHttpCacheHits - 1.3.6.1.4.1.7146.1.2.2.2.1.24] | ||
Brocade ZXTM - Virtual Server HTTP Rewrites | brocade.zxtm.virtual.server.http.rewritten.cookies | Virtual Server - HTTP Cookies Rewritten | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server HTTP Cookies Rewritten (HTTP Set-Cookie headers,supplied by a node,that have been rewritten).[ZXTM-MIB-SMIv2::virtualserverHttpRewriteCookie - 1.3.6.1.4.1.7146.1.2.2.2.1.23] | |
brocade.zxtm.virtual.server.http.rewritten.location.headers | Virtual Server - HTTP Location Headers Rewritten | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server HTTP Location Headers Rewritten (HTTP Location headers,supplied by a node,that have been rewritten).[ZXTM-MIB-SMIv2::virtualserverHttpRewriteLocation - 1.3.6.1.4.1.7146.1.2.2.2.1.22] | ||
Brocade ZXTM - Virtual Server Responses | brocade.zxtm.virtual.server.discards | Virtual Server - Discards | psec | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server Discards (Connections discarded by this virtual server).[ZXTM-MIB-SMIv2::virtualserverDiscard - 1.3.6.1.4.1.7146.1.2.2.2.1.12] |
brocade.zxtm.virtual.server.direct.replies | Virtual Server - Direct Replies | psec | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server Direct Replies (Direct replies from this virtual server,without forwarding to a node).[ZXTM-MIB-SMIv2::virtualserverDirectReplies - 1.3.6.1.4.1.7146.1.2.2.2.1.13] | |
brocade.zxtm.virtual.server.conn.timeouts | Virtual Server - Connection Timeouts | psec | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server Connection Timeouts (Connections closed by this virtual server because the 'connect_timeout' interval was exceeded).[ZXTM-MIB-SMIv2::virtualserverConnectTimedOut 1.3.6.1.4.1.7146.1.2.2.2.1.14] | |
brocade.zxtm.virtual.server.data.timeouts | Virtual Server - Data Timeouts | psec | It monitors Brocade ZXTM (Virtual Traffic Manager) - Virtual Server Data Timeouts (Connections closed by this virtual server because the 'timeout' interval was exceeded).[ZXTM-MIB-SMIv2::virtualserverDataTimedOut - 1.3.6.1.4.1.7146.1.2.2.2.1.15] | |
Brocade ZXTM - Virtual Server Traffic | brocade.zxtm.virtual.server.traffic.out | Virtual Server - Traffic Out | Kbps | It monitors Brocade ZXTM (Virtual Traffic Manager) - Outgoing traffic from virtual server to clients.[ZXTM-MIB-SMIv2::virtualserverBytesOut - 1.3.6.1.4.1.7146.1.2.2.2.1.32] |
brocade.zxtm.virtual.server.traffic.in | Virtual Server - Traffic In | Kbps | It monitors Brocade ZXTM (Virtual Traffic Manager) - Incoming traffic from clients to this virtual server.[ZXTM-MIB-SMIv2::virtualserverBytesIn - 1.3.6.1.4.1.7146.1.2.2.2.1.31] |